polymeric hemoglobin solution Search Results


90
Somatogen Inc polymeric hemoglobin solution
Apparent molecular weights and particle sizes of dihemoglobins.
Polymeric Hemoglobin Solution, supplied by Somatogen Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/polymeric hemoglobin solution/product/Somatogen Inc
Average 90 stars, based on 1 article reviews
polymeric hemoglobin solution - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Northfield Laboratories polymerized hemoglobin solution (hypo with a polymerized hemoglobin solution)
Apparent molecular weights and particle sizes of dihemoglobins.
Polymerized Hemoglobin Solution (Hypo With A Polymerized Hemoglobin Solution), supplied by Northfield Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/polymerized hemoglobin solution (hypo with a polymerized hemoglobin solution)/product/Northfield Laboratories
Average 90 stars, based on 1 article reviews
polymerized hemoglobin solution (hypo with a polymerized hemoglobin solution) - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Biopure Corporation polymerized ultrapurified bovine- hemoglobin solution tpcbh
Apparent molecular weights and particle sizes of dihemoglobins.
Polymerized Ultrapurified Bovine Hemoglobin Solution Tpcbh, supplied by Biopure Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/polymerized ultrapurified bovine- hemoglobin solution tpcbh/product/Biopure Corporation
Average 90 stars, based on 1 article reviews
polymerized ultrapurified bovine- hemoglobin solution tpcbh - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
Biopure Corporation blood substitutes polymerized hemoglobin solutions oxyglobin
Apparent molecular weights and particle sizes of dihemoglobins.
Blood Substitutes Polymerized Hemoglobin Solutions Oxyglobin, supplied by Biopure Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/blood substitutes polymerized hemoglobin solutions oxyglobin/product/Biopure Corporation
Average 90 stars, based on 1 article reviews
blood substitutes polymerized hemoglobin solutions oxyglobin - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

Image Search Results


Apparent molecular weights and particle sizes of dihemoglobins.

Journal: Journal of Functional Biomaterials

Article Title: Monodisperse 130 kDa and 260 kDa Recombinant Human Hemoglobin Polymers as Scaffolds for Protein Engineering of Hemoglobin-Based Oxygen Carriers

doi: 10.3390/jfb3010061

Figure Lengend Snippet: Apparent molecular weights and particle sizes of dihemoglobins.

Article Snippet: Initially, Somatogen approached the generation of a polymeric hemoglobin solution via chemical crosslinking of rHb1.1 with glutaraldehyde [ ].

Techniques: Sedimentation

Determination of circulating halflife and hemodynamic response of di-Hb in vivo ( a ) Circulating halflife was determined in male Sprague-Dawley rats. Top-load doses of protein were administered via intravenous infusion to six rats each in experimental (SGE 953, filled circles) and control (rHb1.1, open circles) groups. Time-dependent curves of plasma hemoglobin concentrations are shown; ( b ) Hemoglobin concentrations in peritoneal lavage fluid at two time points following administration of rHb1.1 (open bars) or dihemoglobin from SGE 953 (filled bars) to separate groups of Balb/C mice; ( c ) Changes in mean arterial pressure following administration of hemoglobins to conscious, unrestrained rats. Top-load doses of rHb1.1 (filled triangles, orange), SGE 953 di-Hb (filled circles, blue), crosslinked SGE 2812 tetra-Hb (filled crosses, green), or HSA (50 mg/mL, filled squares, purple) were administered to separate groups of rats (n = 6 in all groups).

Journal: Journal of Functional Biomaterials

Article Title: Monodisperse 130 kDa and 260 kDa Recombinant Human Hemoglobin Polymers as Scaffolds for Protein Engineering of Hemoglobin-Based Oxygen Carriers

doi: 10.3390/jfb3010061

Figure Lengend Snippet: Determination of circulating halflife and hemodynamic response of di-Hb in vivo ( a ) Circulating halflife was determined in male Sprague-Dawley rats. Top-load doses of protein were administered via intravenous infusion to six rats each in experimental (SGE 953, filled circles) and control (rHb1.1, open circles) groups. Time-dependent curves of plasma hemoglobin concentrations are shown; ( b ) Hemoglobin concentrations in peritoneal lavage fluid at two time points following administration of rHb1.1 (open bars) or dihemoglobin from SGE 953 (filled bars) to separate groups of Balb/C mice; ( c ) Changes in mean arterial pressure following administration of hemoglobins to conscious, unrestrained rats. Top-load doses of rHb1.1 (filled triangles, orange), SGE 953 di-Hb (filled circles, blue), crosslinked SGE 2812 tetra-Hb (filled crosses, green), or HSA (50 mg/mL, filled squares, purple) were administered to separate groups of rats (n = 6 in all groups).

Article Snippet: Initially, Somatogen approached the generation of a polymeric hemoglobin solution via chemical crosslinking of rHb1.1 with glutaraldehyde [ ].

Techniques: In Vivo, Control, Clinical Proteomics